(1) Windows shall be opened outside buildings with 7 floors and above.
(2) Window glass with an area of more than 1.5m2 or floor to ceiling window whose bottom edge (the dividing line between the transparent part of the glass and the opaque part covered by the glass installation material after the glass is assembled in the frame) is less than 500mm away from the final decoration surface.
(3) Curtain wall (except full glass curtain).
(4) Inclined assembly window, all kinds of ceiling (including skylight, daylighting roof) and ceiling.
(5) Sightseeing elevator and its outer enclosure.
(6) Indoor partition and screen.
(7) Handrails of stairs, balconies, platforms, corridors and guardrails in atrium.
(8) Floor panel for bearing pedestrian walking.
(9) Entrances and exits, hallways and other parts of public buildings (including 1. Door glass 2. Glass installed above the door 3. Glass installed on both sides of the door. The distance between the vertical edge close to the doorway opening and the doorway opening is less than 300mm